Specications
Electrical Requirements
MCC-1024-6A
Primary Input Power: 120 volts, 60 Hz, 2 Amps maximum
Indicating Current: 24VDC unltered, 5 Amps maximum
Standby Power: 24VDC Standby Batteries
Charging Capability: 10-24 AH batteries
MCC-1024-12A
Primary Input Power: 120 volts, 60 Hz, 4 Amps maximum
Indicating Current: 24VDC unltered, 10 Amps maximum
Standby Power: 24VDC Standby Batteries
Charging Capability: 17-40 AH batteries
Enclosures
BB-1024 Backbox: 26”H x 14.5”W x 4.5”D
BB-1072 Backbox: 33”H x 22.25”W x 7.5”D
Remote Annunciator Enclosures
BB-1001 Enclosure: 9”H x 12.75”W x 1.2”D
BB-1002 Enclosure: 18”H x 12.75”W x 1.2”D
BB-1003 Enclosure: 26.4”H x 12.75”W x 1.2”D
BB-1008 Enclosure: 33”H x 22.5”W x 1.25”D
BB-1012 Enclosure: 45”H x 22.5”W x 1.25”D
Ordering Information
Model Description
Chassis
MCC-1024-6A Main Chassis c/w 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits, 4 Class A/B (Style Z/Y) Indicating
circuits, a common control and an identication display board for up to 24 points and a 6 Amp Power Supply
(Expandable with up to two adder modules of any type plus one of a UDACT-300A Digital Communicator or PR-300
Polarity Reversal/City Tie Module)
MCC-1024-12A Main Chassis c/w 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits, 4 Class A/B (Style Z/Y) Indicating
circuits, a common control and an identication display board for up to 24 points and a 12 Amp Power Supply
(Expandable with up to two adder modules of any type plus one of a UDACT-300A Digital Communicator or PR-300
Polarity Reversal/City Tie Module)
ECH-1048 Expander Chassis c/w space to add up to 6 Adder Modules
RTI-1 Remote Trouble Indicator
Adder Modules
DM-1008A Eight Class B (Style B) or 4 Class A (Style D) Initiating Circuit Module
SGM-1004A Four Class A/B (Style Z/Y) Indicating Circuit Module (Rated at 1.7 Amps per circuit)
RM-1008A Eight Relay Circuit Module c/w eight Form C relays (Rated for 28 VDC @ 1 Amp. max. per relay)
Auxiliary Modules
UDACT-300A Digital Alarm Communication Transmitter/Dialer Module
PR-300 Polarity Reversal and City Tie Module
Enclosures
BB-1024 Backbox enclosure c/w keylock door. Houses one MCC-1024-6A Main Chassis or MCC-1024-12A Main Chassis
BB-1072 Backbox enclosure c/w keylock door. Houses one MCC-1024-6A Main Chassis or MCC-1024-12A Main Chassis
and one ECH-1048 Expander Chassis
(Addsufx‘R’forU.S.andInternationalenclosure.)
Flush Trim Rings
FA-UNIV-TRB Black Semi-Flush Trim Ring for BB-1024 Enclosure
FA-1072TR Black Semi-Flush Trim Ring for BB-1072 Enclosure
Remote Annunciators
RAM-1032 Main Annunciator Chassis c/w Common Control Features, Indicators and 32 Bi-Coloured LEDs
RAM-1032TZ Main Annunciator Chassis c/w Common Control Features, Indicators and 32 Bi-Coloured LEDs & 32 Trouble LEDs
RAM-1016 Main Annunciator Chassis c/w Common Control Features, Indicators and 16 Bi-Coloured LEDs
RAX-1048 Adder Annunciator Chassis c/w 48 Bi-Coloured LEDs
RAX-1048TZ Adder Annunciator Chassis c/w 48 Bi-Coloured LEDs and 48 Trouble LEDs
BB-1001 Annunciator backbox with keylock door (Houses 1 module)
BB-1002 Annunciator backbox with keylock door (Houses 2modules)
BB-1003 Annunciator backbox with keylock door (Houses 3 modules)
BB-1008 Annunciator backbox with keylock door (Houses 8modules)
BB-1012 Annunciator backbox with keylock door (Houses 12 modules)
Note:ForU.S.andInternationalenclosureaddsufx‘R’(RedExterior)
ForStainlessSteelenclosureaddsufx‘S’
Batteries
BA-110 12 Volt, 10 Amp/Hr. Battery - 2 pcs required per panel
BA-117 12 Volt, 17 Amp/Hr. Battery - 2 pcs required per panel
BA-124 12 Volt, 24 Amp/Hr. Battery - 2 pcs required per panel
BA-140 12 Volt, 40 Amp/Hr. Battery - 2 pcs required per panel
Canada
25 Interchange Way
Vaughan, Ontario L4K 5W3
Telephone: (905) 660-4655
Fax: (905) 660-4113
Distributed by:
CAT. 5620
Rev. 4
NOT TO BE USED FOR INSTALLATION PURPOSES.
U.S.A.
60 Industrial Parkway
Cheektowaga, New York 14227
Toll Free: (888) 660-4655
Fax Toll Free: (888) 660-4113